| Detection |
| Measurement Type |
Inductive, non-contact detection of metallic objects |
| Thread Sizes |
M8 × 1 / M12 × 1 / M18 × 1 / M30 × 1.5 |
| Mounting Styles |
Flush / non-flush |
| Standard Sensing Distance |
M8/M12/M18/M30: flush 1.5/2/5/10 mm; non-flush 2/4/8/15 mm; ±10% |
| Enhanced Sensing Distance |
M8/M12/M18/M30: flush 2/4/8/15 mm; non-flush 4/8/16/30 mm; ±10%; DC 3-wire only |
| DC 2-Wire Sensing Distance |
M8/M12/M18/M30: flush 1.5/2/5/10 mm; non-flush 2/4/8/15 mm; ±10% |
| Standard / DC 2-Wire Operating Distance |
M8/M12/M18/M30: flush 0–1.2/0–1.6/0–4/0–8 mm; non-flush 0–1.6/0–3.2/0–6.4/0–12 mm |
| Enhanced Operating Distance |
M8/M12/M18/M30: flush 0–1.6/0–3.2/0–6.4/0–12 mm; non-flush 0–3.2/0–6.4/0–12.8/0–24 mm |
| Standard Target |
Mild steel (Q235A / ASTM A36 equivalent); target size depends on housing and mounting |
| Hysteresis |
1–15% of sensing distance |
| Repeatability |
<5% of sensing distance |
| Standard / DC 2-Wire Response Frequency |
M8/M12/M18/M30: flush 2/1.5/1/0.5 kHz; non-flush 1/0.8/0.4/0.1 kHz |
| Enhanced Response Frequency |
M8/M12/M18/M30: flush 1.5/1/0.5/0.25 kHz; non-flush 1/0.8/0.4/0.1 kHz |
| Power and Output |
| Supply Voltage |
10–30 V DC |
| Standard DC 3-Wire Current Consumption |
<15 mA (M8/M12/M18); <20 mA (M30) |
| Enhanced DC 3-Wire Current Consumption |
<10 mA (M8); <15 mA (M12/M18); <22 mA (M30) |
| Output Type |
NPN or PNP open-collector, DC 3-wire; DC 2-wire options |
| Output State |
NO / NC; NO + NC dual output available for DC 3-wire only |
| DC 3-Wire Load Current |
<100 mA (M8); <200 mA (M12/M18/M30) |
| DC 3-Wire Residual Voltage |
<2 V at 100 mA; <2.5 V at 200 mA; 2 m cable |
| DC 2-Wire Load Current / Residual Voltage |
<100 mA / <5 V |
| Indicator |
Yellow LED; illuminated at output ON; 360° ring indication |
| Circuit Protection |
Reverse polarity, output short-circuit and surge absorption |
| Material and Environment |
| Housing Material |
Nickel-plated brass; M8 housing: stainless steel |
| Cap Materials |
Front: PBT; rear: PC |
| Ingress Protection |
IP67 (IEC) |
| Operating / Storage Temperature |
−25 to +70 °C |
| Operating / Storage Humidity |
35–95% RH |
| Dielectric Strength |
1,000 V AC, 50/60 Hz, 1 min; live parts to housing |
| Insulation Resistance |
>50 MΩ at 500 V DC; live parts to housing |
| Vibration Resistance |
10–55 Hz; 1.5 mm double amplitude; 2 h per axis (X/Y/Z) |
| Shock Resistance |
500 m/s² (approximately 50 G); 3 shocks per axis (X/Y/Z) |
| Connection and Installation |
| Lead-Wire Connection |
Standard 2 m cable |
| Connector Options |
M12 × 1, 4-pin; M8 4-pin (DC 3-wire only); M8 3-pin; according to model |
| Mounting Torque — M8/M12/M18/M30 |
5.5 / 10 / 30 / 150 N·m |
| Target Correction Factors |
Mild steel: 1.0; SUS304: approximately 0.65; brass: approximately 0.42; aluminum: approximately 0.41 |
| Installation Spacing |
Follow the model-specific minimum face-to-face, side-by-side and background-metal clearances in the datasheet |
| Dimensions and Weight |
| Lead-Wire Housing Length |
40 mm; rear sections differ by housing size |
| Across Flats — M8/M12/M18/M30 |
13 / 17 / 24 / 36 mm |
| Lead-Wire Cable Diameter |
M8: Ø3.8 mm; M12/M18/M30: Ø4.8 mm |
| Connector Overall Length |
55 mm; reference length 44.5 mm (M8/M12) or 44 mm (M18/M30) |
| Approximate Lead-Wire Weight — M8/M12/M18/M30 |
50 / 95 / 115 / 190 g |
| Approximate Connector Weight — M8/M12/M18/M30 |
20 / 30 / 60 / 130 g |