Skip to results list

Load Cells

( 4 items )

Filter

  • SX-FLAMB Series

    The SensorsX SX-FLAMB series is a compact, low-profile load cell for force measurement in automotive press-fitting and automation equipment. It features stainless steel construction and good resistance to off-center loading. The load cell provides an mV/V bridge output, with optional transmitter modules for conditioned analog or digital outputs. Output configuration and supply requirements depend on the selected model and transmitter module.

    • Capacity: 50 kg–20 t; model-dependent.
    • Sensitivity: 1.5–2.0 mV/V ±10%.
    • L output code: 1.2–2.0 mV/V.
    • Non-linearity / hysteresis / repeatability: ≤ ±0.1% F.S.
    • Creep: ±0.05% F.S. / 30 min.
    • Sensitivity / zero temperature drift: ±0.05% F.S. / 10 °C.
    • Safe / ultimate overload: 120% / 150% F.S.
    • Excitation: 5–12 V DC recommended; 15 V DC maximum for mV/V output.
    • Input / output resistance: 750 ±10 Ω / 700 ±3 Ω.
    • Optional transmitter: analog or digital outputs; supply depends on module.
    • Mounting / connection: Bolt mounting; integral 3 m cable.
    • Material / protection: Stainless steel; IP65.
    • Operating temperature: −30 to +80 °C.
  • SX-FLANB Series

    The SensorsX SX-FLANB series is a compact aluminum alloy load cell for small electronic platform scales, portable weighing scales and other electronic weighing systems. It offers good corrosion resistance and long-term stability, with two body sizes available. The smaller version is specified for rated capacities up to 10 kg. The load cell has a nominal output sensitivity of 2.0 mV/V and a recommended bridge excitation voltage of 5–12 V DC. Optional transmitter modules provide conditioned analog or digital outputs, depending on the selected configuration.

    • Measurement range: 1 / 3 / 5 / 10 / 20 / 50 / 100 kg.
    • Sensitivity: 2.0 mV/V ±10%.
    • Non-linearity / hysteresis / repeatability: ≤ ±0.02% F.S.
    • Creep: ±0.02% F.S. / 30 min.
    • Sensitivity / zero temperature drift: ±0.02% F.S. / 10 °C.
    • Safe / ultimate overload: 150% / 300% F.S.
    • Excitation: 5–12 V DC recommended; 15 V DC maximum for mV/V output.
    • Input / output resistance: 400 ±20 Ω / 350 ±5 Ω.
    • Optional transmitter: analog or digital outputs; supply depends on module.
    • Size A: 130 × 30 × 22 mm; 4 × M6 through.
    • Size B: 70 × 15 × 22 mm; capacity ≤10 kg; 4 × M3, 12 mm deep.
    • Mounting / connection: Bolt mounting; direct cable outlet.
    • Material / protection: Aluminum alloy; IP65 (IEC 60529).
    • Operating temperature: −20 to +60 °C.
  • SX-FLPNB Series

    The SensorsX SX-FLPNB series is a spoke-type load cell for weighing and force measurement in industrial automation systems. It features a rugged alloy steel construction, good resistance to lateral forces and off-center loading, and a low center of gravity. Versions with and without a base are available. The load cell has a nominal output sensitivity of 2.0 mV/V and a recommended bridge excitation voltage of 5–12 V DC. Optional transmitter modules provide conditioned analog or digital outputs, depending on the selected configuration.

    • Rated capacity: 0.5–100 t; model-dependent.
    • Sensitivity: 2.0 mV/V ±10%.
    • Non-linearity / hysteresis / repeatability: ≤ ±0.05% F.S.
    • Creep: ±0.03% F.S. / 30 min.
    • Sensitivity / zero temperature drift: ±0.05% F.S. / 10 °C.
    • Safe / ultimate overload: 150% / 300% F.S.
    • Excitation: 5–12 V DC recommended; 15 V DC maximum for mV/V output.
    • Input / output resistance: 380 ±10 Ω / 350 ±3 Ω.
    • Insulation resistance: ≥2,000 MΩ.
    • Optional transmitter: analog or digital outputs; supply depends on module.
    • Version A / B: With base / without base.
    • Optional load buttons: Button 1 / Button 2; capacity-dependent.
    • Mounting / connection: Bolt mounting; direct cable outlet.
    • Material / protection: Alloy steel; IP65.
    • Operating temperature: −20 to +60 °C.
  • SX-FLSNB Series

    The SensorsX SX-FLSNB series is a compression load cell featuring a combined S-beam sensing structure. It uses metal foil strain gauges and incorporates overload protection. The load cell provides stable measurement performance. It is suitable for static and dynamic force measurement and electronic weighing systems. Rated capacities of 5, 10, 30, 100, and 150 kg are available, with a nominal output sensitivity of 2.0 mV/V.

    • Measurement range: 5 / 10 / 30 / 100 / 150 kg.
    • Sensitivity: 2.0 mV/V ±10%.
    • Non-linearity / hysteresis / repeatability: ≤ ±0.05% F.S.
    • Creep: ±0.05% F.S. / 30 min.
    • Sensitivity / zero temperature drift: ±0.05% F.S. / 10 °C.
    • Safe / ultimate overload: 150% / 300% F.S.
    • Excitation: 5–12 V DC recommended; 15 V DC maximum for mV/V output.
    • Input / output resistance: 380 ±10 Ω / 350 ±3 Ω.
    • Insulation resistance: ≥5,000 MΩ.
    • Optional transmitter: analog or digital outputs; supply depends on module.
    • Base plate: 80 × 80 mm; 4 × Φ6.5 mm mounting holes on 65 × 65 mm pattern.
    • Height: 50 mm excluding load button; 55 mm including load button.
    • Load button diameter: Φ10 mm.
    • Mounting / connection: Bolt mounting; direct cable outlet.
    • Material / protection: Alloy steel; IP65.
    • Operating temperature: −20 to +60 °C.