Product Overview
The SX-GSO2TSA Series is a potentiostatic electrochemical sulfur dioxide sensor. Sulfur dioxide and oxygen undergo oxidation–reduction reactions at the working electrode and counter electrode, respectively, generating an electrical current. The output current is proportional to the sulfur dioxide concentration, allowing SO₂ concentration to be determined from the measured current.
Main Features
-
High Accuracy, Long Service Life —— Precise detection with extended operating life
-
Fast Response, Fast Recovery —— Quick response with rapid baseline recovery
-
Low Power, High Sensitivity —— Low power consumption with high sensitivity
-
Wide Linear Range, High Resistance to Interference —— Robust performance across the measurement range
-
High Repeatability and Stability —— Consistent long-term performance
Product Application
Sulfur dioxide detection instruments
|
Industrial on-site sulfur dioxide gas detection
|
|
Livestock-farming sulfur-compound detection
|
Smart municipal sulfur dioxide detection
|
|
Atmospheric / ambient sulfur dioxide detection
|
|
Technical Data
| Measurement |
| Example Model |
SX-GSO2TSA-540 |
| Detection Principle |
Electrochemical, three-electrode |
| Detection Gas |
Sulfur Dioxide (SO₂) |
| Detection Range |
0–20 ppm |
| Maximum Overload Concentration |
100 ppm |
| Sensitivity & Output |
| Sensitivity |
500 ± 100 nA/ppm |
| Zero Drift |
0–1 ppm |
| Resolution |
0.1 ppm |
| Linearity |
Linear |
| Output |
Current proportional to SO₂ concentration |
| Response |
| Response Time |
< 45 s
|
| Repeatability |
2% of output signal |
| Long-Term Stability |
< 2% signal/month |
| Stability & Service Life |
| Shelf Life |
12 months after delivery |
| Service Life |
2 years |
| Electrical Data |
| Bias Voltage |
0 V |
| Load Resistance |
5–30 Ω |
| Environmental Conditions |
| Operating Temperature |
−30°C to +50°C |
| Operating Humidity |
15–90% RH, non-condensing |
| Operating Pressure |
90–110 kPa |
| Mechanical Data |
| Body Diameter |
Ø20 mm, without label |
| Body Height |
16.95 mm |
| Pin Length |
4.4 mm |
| Pin Diameter |
Ø1.5 mm |
| Dimensional Tolerance |
±0.2 mm |
| Cross-Interference |
| Carbon Monoxide (CO) |
Test concentration: 500 ppm; Reading: 1 ppm SO₂ |
| Hydrogen Sulfide (H₂S) |
Test concentration: 25 ppm; Reading: 0 ppm SO₂ |
| Ammonia (NH₃) |
Test concentration: 100 ppm; Reading: 0 ppm SO₂ |
| Hydrogen (H₂) |
Test concentration: 1000 ppm; Reading: 1 ppm SO₂ |
| Nitric Oxide (NO) |
Test concentration: 20 ppm; Reading: 0 ppm SO₂ |
| Nitrogen Dioxide (NO₂) |
Test concentration: 20 ppm; Reading: −24 ppm SO₂ |
| Chlorine (Cl₂) |
Test concentration: 20 ppm; Reading: −5 ppm SO₂ |
Certifications & Compliance