Home / Products / Pressure Transmitters / SX-PDDB Series
Skip to product information
SX-PDDB Series
1/7

SX-PDDB Series

The SX-PDDB series remote seal differential pressure transmitter uses a diaphragm seal assembly to isolate the sensor from harsh process media, providing reliable measurement of differential pressure, level, density, and flow. With flexible remote seal configurations, multiple fill fluids, wide measurement range, and robust industrial design, it is suitable for demanding applications in chemical, oil & gas, power, pharmaceutical, and water treatment industries.

  • Measurement Range: 0–1 kPa to 0–2 MPa
  • Output: 4–20 mA / HART / Modbus / Profibus PA
  • Accuracy: ±0.075% FS
  • Power Supply: 9–36 V DC
  • Ingress Protection: IP67
  • Ambient Temperature: Up to −40 to +85°C, depending on configuration
  • Process Temperature: −30 to +400°C
  • Remote Seal: Flush or insertion type; DN50 / DN80 / DN100 / 2" / 3" / 4" flanges
  • Fill Fluids: Silicone oil / HT silicone oil / Ultra-HT silicone oil / Food-grade fluid / Ultra-LT fluid
  • Diaphragm Materials: 316L stainless steel / Hastelloy C / Tantalum
  • Explosion Protection: Intrinsic Safety ATEX / Flameproof ATEX (optional)
Ordering Code
$888.00

Product Overview

The SX-PDDB series remote seal differential pressure transmitter uses a diaphragm seal assembly to prevent process media from directly entering the pressure sensor of the differential pressure transmitter; pressure is transmitted via fill fluid (such as silicone oil) through capillary tubing. The SX-PDDB series is used to measure level, density, pressure, and flow of liquids, gases, or steam, converting the measurement to a 4–20 mA DC HART signal output. It also supports HART, Profibus PA, and RS-485-Modbus communication protocols. The zero-based measuring is 0–1 kPa to 2 MPa (0–0.145 to 290 psi). Remote seal flange rated pressures are: 1.6/4 MPa, 6.4 MPa, 10 MPa, 150 psi, 300 psi, or 600 psi.


Typical Measurements

  • Differential pressure
  • Level
  • Density

Main Features

  • Wide Measuring Range —— 0–1 kPa to 0–2 MPa with continuous turndown adjustment
  • Remote Seal Protection —— Diaphragm seal assembly isolates process media from the sensor for reliable measurement in harsh applications
  • Multiple Fill Fluids —— Silicone oil | High-temperature silicone oil | Ultra-high-temperature silicone oil | Food-grade fluid | Ultra-low-temperature fluid
  • Flexible Flange Options —— Flush or insertion type; DN50 / DN80 / DN100 / 2" / 3" / 4" flanges compliant with DIN 2501 and ANSI B16.5
  • Flexible Capillary Configurations ——1–12 m capillary length with 304 or 316 stainless steel material; optional PVC protection sheath
  • Multiple Communication Protocols —— 4–20 mA HART | RS-485 Modbus | Profibus PA
  • Hazardous Area Certification —— Intrinsic Safety ATEX | Flameproof ATEX (optional)
  • Rugged Industrial Housing —— Epoxy-coated aluminum alloy or 316 stainless steel housing; IP67 protection with 360° rotation capability

Product Application

Industries Served

Oil & Gas Power Generation Food & Beverage
Petrochemical & Chemical Water & Wastewater Pharmaceutical
Metal Smelting Pulp & Paper Marine & Offshore

Technical Data

Measurement
Measured Parameters Differential pressure 
Measuring Range 0–1 kPa to 0–2 MPa (0–0.145 to 290 psi)
Span Adjustment Continuous adjustment from −100% URL to +100% URL
Response Time Sensor + seal time constant 0.2–6 s; adjustable damping 0.1–60 s
Remote Seal System
Remote Seal Design Diaphragm seal assembly isolates process media from sensor
Remote Seal Type Flush type or insertion type
Flange Sizes DN50 / DN80 / DN100 / 2" / 3" / 4"
Flange Standards DIN 2501 / ANSI B16.5
Capillary Length 1–12 m
Capillary Material 304 stainless steel / 316 stainless steel (optional PVC sheath)
Fill Fluids Silicone oil / High-temperature silicone oil / Ultra-high-temperature silicone oil / Food-grade fluid / Ultra-low-temperature fluid
Power & Output
Supply Voltage 9–36 V DC (13.5 V DC minimum with LCD/OLED display)
Analog Output 4–20 mA, 2-wire, loop-powered; linear or square-root selectable
Digital Communication HART / RS-485 Modbus / Profibus PA
Cable Entry M20×1.5 or ½ NPT female thread
Wire Cross-Section 0.5–2.5 mm²
Environmental Conditions
Ambient Temperature Maximum +85°C (depends on fill fluid)
Process Temperature −30 to +400°C
Ingress Protection IP67 (IEC 60529)
Shock Resistance 50 g / 11 ms (IEC 60068-2-27)
Vibration Resistance 2 g up to 500 Hz (IEC 60068-2-6)
Process Connection & Materials
Pressure Connection ¼" NPT female & 7/16" UNF female (transmitter body); ANSI B16.5 / DIN 2501 remote seal flange
Remote Seal Rated Pressure ANSI B16.5: 150 psi–600 psi; DIN 2501: PN1.6 MPa–PN10 MPa
Diaphragm Materials 316L stainless steel / Hastelloy C / Tantalum
Process Flange Material 304 stainless steel
Housing Material Epoxy-coated aluminum alloy / 316 stainless steel