| Measurement |
| Model |
SX-GMSA Series |
| Product Type |
Industrial smart gas sensor module |
| Detection Method |
Natural diffusion; flow-through version available upon request |
| Sensor Technologies |
Electrochemical / Catalytic combustion / Infrared / Photoionization (PID) |
| Detection Gas |
O₂, CO, H₂S, NO, NO₂, SO₂, CO₂, O₃, NH₃, CH₄, combustible gases, VOCs and other gases |
| Detection Range |
Depends on the target gas and selected sensor |
| Warm-Up Time |
30–60 s |
| Accuracy & Output |
| Accuracy |
Depends on target gas and sensor technology |
| Resolution |
1 ppb to 1% VOL, depending on configuration |
| Communication Protocol |
Modbus RTU |
| Digital Output |
UART or RS-485, selectable |
| Analog Output |
0–2 V, optional |
| Output Type |
Standardized digital concentration output; optional analog-voltage output |
| Baud Rate |
9600 bps |
| Data Format |
8 data bits, 1 stop bit, no parity |
| Default Modbus Address |
0xFF |
| Standard Detection Options |
| Oxygen (O₂) |
Range: 0–30% VOL; Accuracy: ±3% F.S.; Resolution: 0.1% VOL |
| Carbon Monoxide (CO) |
Range: 0–1000 ppm; Accuracy: ±5 ppm or ±10%, whichever is greater; Resolution: 1 ppm |
| Hydrogen Sulfide (H₂S) |
Range: 0–100 ppm; Accuracy: ±2 ppm or ±10%, whichever is greater; Resolution: 1 ppm |
| Carbon Dioxide (CO₂) |
Range: 0–5% VOL or 0–5000 ppm; Accuracy: ±(0.05 + 5% of reading); Resolution: 0.01% VOL or 1 ppm |
| Methane (CH₄) |
Range: 0–5% VOL or 0–100% VOL; Accuracy: ±5% F.S.; Resolution: 0.01% VOL or 1% VOL |
| Combustible Gas |
Range: 0–100% LEL; Accuracy: ±5% F.S.; Resolution: 1% VOL |
| VOC / PID |
Range: 0–10 ppm, 0–40 ppm, or 0–100 ppm; Accuracy and resolution depend on the selected configuration |
| Stability & Service Life |
| Electrochemical Sensor Life |
2 years |
| Infrared Sensor Life |
5 years |
| Catalytic-Combustion Sensor Life |
2 years |
| Calibration |
Factory-calibrated; supports up to six calibration points |
| Power |
| Supply Voltage |
5–24 V DC |
| Electrochemical Sensor Power |
Typically 15 mW |
| Infrared Sensor Power |
Typically 100 mW |
| PID Sensor Power |
Typically 110 mW |
| Catalytic-Combustion Sensor Power |
Typically 300 mW |
| Power Consumption |
Depends on the selected sensor technology |
| Environmental Conditions |
| Operating Temperature |
−20°C to +50°C |
| Operating Humidity |
10%–95% RH, non-condensing |
| Mechanical Data |
| Housing Material |
High-strength aluminum alloy |
| Overall Dimensions |
Ø41 × 67 mm |
| Weight |
35 g |
| Connector |
5-pin terminal connector |
| Connector Pitch |
1.25 mm |
| Wiring |
GND / VCC / RX or 485B / TX or 485A / Analog output |