Home / Products / Carbon Dioxide Sensors (CO2) / SX-GCO2NSA Series
Skip to product information
SX-GCO2NSA Series
1/3

SX-GCO2NSA Series

The SX-GCO2NSA Series is a compact NDIR carbon dioxide sensor designed for reliable CO₂ measurement in air. It offers selectable ranges from 0–5000 ppm up to 0–100% Vol, fast response, low power consumption, and built-in temperature compensation. With UART and 0.4–2 V analog outputs, it is suitable for HVAC, indoor air-quality monitoring, industrial processes, agriculture, and safety systems.

  • Accuracy: ±(50 ppm + 5% of reading) / ±(0.05% Vol + 5% of reading)
  • Measurement Range: 0–5000 ppm / 0–5% Vol / 0–10% Vol / 0–20% Vol / 0–50% Vol / 0–100% Vol
  • Output Signal: UART / 0.4–2 V analog voltage
  • Power Supply: 3.6–5.5 V DC
  • Explosion Protection: Ex ia I Ma
  • Ingress Protection: IP54
  • Response Time: T90 < 30 s
  • Operating Temperature: −20°C to +60°C
  • Service Life: > 5 years
Ordering Code
$140.00

Product Overview

The SX-GCO2NSA Series is a compact NDIR carbon dioxide sensor for detecting COin air. It operates without oxygen dependency and integrates temperature compensation for stable long-term performance. The sensor combines infrared absorption measurement, micro-machined construction, and optimized circuit design to provide reliable CO₂ measurement in a compact package.

Main Features

  • High Sensitivity & High Resolution —— Precise detection across the measurement range
  • Low Power, Fast Response —— Quick response with low power consumption
  • Multiple Output Options —— UART and analog voltage output available
  • Temperature Compensation —— Built-in compensation with excellent linear output
  • Excellent Stability —— Consistent long-term performance
  • Poisoning & Humidity Resistant —— Resistant to water vapor interference and poisoning, long service life

Product Application

HVAC & Indoor Air Quality Monitoring
Industrial Process & Safety Monitoring
Agriculture & Livestock Production Monitoring

Technical Data

Measurement
Model SX-GCO2NSA
Detection Principle Non-dispersive infrared (NDIR)
Detection Gas Carbon dioxide (CO₂)
Detection Range 0–5000 ppm / 0–5% Vol / 0–10% Vol / 0–20% Vol / 0–50% Vol / 0–100% Vol
Temperature Compensation Built-in
Accuracy & Resolution
0–5000 ppm Range 10 ppm resolution; ±(50 ppm + 5% of reading) accuracy
0–5% Vol Range 0.01% Vol resolution; ±(0.05% Vol + 5% of reading) accuracy
0–10% Vol Range 0.01% Vol resolution; ±(0.05% Vol + 5% of reading) accuracy
0–20% Vol Range 0.1% Vol resolution; ±(0.05% Vol + 5% of reading) accuracy
0–50% Vol Range 0.1% Vol resolution; ±(0.05% Vol + 5% of reading) accuracy
0–100% Vol Range 0.1% Vol resolution; ±(0.05% Vol + 5% of reading) accuracy
Response
Warm-up Time 1 min
Response Time T90 ≤ 30 s
Output & Communication
Output Type UART and 0.4–2 V analog voltage
Interface Level 3.0 V
Communication Protocol Modbus RTU
Physical Interface TTL232, TTL-level UART
Baud Rate 9600
Data Format 8 data bits / 1 stop bit / No parity
Default Address 0xFF
Power
Supply Voltage 3.6–5.5 V DC
Average Current < 60 mA
Intrinsic Safety
Protection Type Intrinsic safety
Explosion Protection Marking Ex ia I Ma
Maximum Input Voltage / Current Ui 5.5 V / Ii 125 mA
Maximum Input Power Pi 0.172 W
Internal Capacitance / Inductance Ci 10.92 µF / Li 0 µH
Environmental Conditions
Operating Temperature −20°C to +60°C
Operating Humidity 0–95% RH, non-condensing
Ingress Protection IP54, according to IEC 60529
Mechanical Data
Dimensions
Ø20 × 21.4 mm
Weight 35 g
Housing Dimension Tolerance ±0.2 mm
Number of Pins 5
Service Life
Service Life
> 5 years
Recommended Calibration Interval 6 months

Certifications & Compliance

Related Products

Ready to upgrade your sensing infrastructure?

You can directly input your requirements and the AI ​​will automatically match the most suitable model.