Product Overview
This high-precision current transducer uses fluxgate technology to measure DC, AC, pulsed and non-sinusoidal currents with galvanic isolation. Its nominal input is ±500 A DC or 353 A AC RMS. A conversion ratio of 1:2,000 provides a nominal ±250 mA output at ±500 A DC input. It offers 100 ppm accuracy at 25 °C and a DC–150 kHz frequency bandwidth (−3 dB). The transducer operates from a dual ±15 V supply, with a green LED indicating normal operation.
Main Features
-
Accuracy: 100 ppm at 25 °C.
-
Frequency bandwidth: DC–150 kHz (−3 dB).
-
Insulation withstand voltage: 5 kV AC (50 Hz, 1 min).
-
Response time: ≤1 µs at 100 A/µs, 10%–90%.
-
Zero offset current: 3 µA at 25 °C.
-
Green LED operating status indicator.
Product Application
Typical Applications
| Electrical test and measurement instruments |
Medical equipment |
Precision current measurement and calibration systems |
| Laboratory testing and measurement |
High-precision power supplies |
Electric and hybrid vehicles |
Technical Data
| Measurement |
| Measuring Principle |
Fluxgate; galvanically isolated DC, AC, pulsed and non-sinusoidal current measurement |
| Primary Nominal DC Current |
±500 A |
| Primary Nominal AC RMS Current |
353 A |
| Primary Measuring Range |
−900 to +900 A |
| Output-to-Input Ratio |
1:2,000 |
| Power & Output |
| Supply Voltage |
Dual (bipolar) ±15 V (±5%) |
| Current Consumption |
15 mA + primary current / 2,000 |
| Secondary Nominal Output Current |
±250 mA |
| Measuring Resistance |
0–34 Ω at ±500 A maximum; 0–10 Ω at ±900 A maximum (±15 V supply) |
| Secondary Coil Resistance |
16 Ω at 85 °C |
| Insulation Withstand Voltage |
5 kV AC, 50 Hz, 1 min |
| Mechanical & Connection |
| Aperture |
Ø30 mm |
| Electrical Connection |
4 terminals: positive supply, negative supply, current output and ground |
| Weight |
253 g |
| Performance |
| Accuracy |
100 ppm at 25 °C |
| Linearity |
20 ppm over 0 to ±500 A |
| Zero Offset Current |
3 µA at 25 °C |
| Offset Temperature Coefficient |
5 µA at zero primary current, −40 to +85 °C |
| Response Time |
≤1 µs at 100 A/µs, 10%–90% |
| Frequency Bandwidth |
DC–150 kHz (−3 dB) |
| Tracked Current Rate of Change |
>100 A/µs |
| Environmental Conditions |
| Operating Temperature |
−40 to +85 °C |
| Storage Temperature |
−40 to +125 °C |
| Primary Conductor Temperature |
Cable or busbar temperature must not exceed 100 °C |