Home / Products / Ultrasonic Flow Sensors / SX-FULB Series
Ir directamente a la información del producto
SX-FULB Series
1/2

SX-FULB Series

The SensorsX SX-FULB Series is a clamp-on ultrasonic flowmeter designed for non-invasive liquid flow measurement. It installs directly on the outside of the pipe without cutting the pipe or contacting the fluid, providing accurate measurement with no pressure loss or contamination. It supports multiple pipe materials and offers RS485 Modbus RTU, 4–20 mA, and NPN/PNP output options.

  • Accuracy: ±1% F.S.
  • Repeatability: 0.15% F.S.
  • Pipe Size Range: DN8–DN20 (¼"–¾")
  • Flow Range: 1.0–100 L/min
  • Output Signal: RS485 Modbus RTU / 4–20 mA / NPN/PNP
  • Power Supply: 20–30 V DC
  • Ingress Protection: IP54
  • Display: Rotatable TFT-LCD
  • Liquid Temperature: 0 to +85°C (32 to +185°F)
  • Ambient Temperature: −10 to +60°C (14 to 140°F)
  • Pipe Materials: Stainless Steel / Carbon Steel / Copper / PVDF / PVC / PPR / PPH / PFA / HDPE
  • Installation: Clamp-on, Non-invasive, No Pipe Cutting
Ordering Code
$461.00

Product Overview

The SX-FULB Series clamp-on ultrasonic flowmeter is a non-contact, non-invasive liquid flow measurement device. Based on the ultrasonic transit-time principle, it measures liquid flow inside the pipe without cutting the pipe or interrupting the process. The clamp-on design provides no pressure loss and no process-fluid contact, making it suitable for flow monitoring and management in industrial applications

Typical Measurements 
  • Instantaneous flow rate
  • Accumulated flow total
  • Flow velocity
  • Signal quality

Main Features

  • Non-Contact, Non-Invasive —— No pipe cutting or wall damage required; clamp-on installation with a 
    single screwdriver
  • Transit-Time Ultrasonic Principle —— Rapidly and accurately measures liquid flow inside the pipe without 
    interrupting the process
  • High Accuracy & Repeatability —— Accuracy ±1 % F.S.; repeatability 0.15 % F.S.
  • No Pressure Loss, No Contamination  —— Completely external installation; no contact with process fluid
  • One Clamp, Two Pipe Sizes —— Reversing the base bracket 180° selects between two supported pipe diameters
  • Multiple Alarm Output Modes —— Instantaneous flow mode, zone mode, and totalizer mode
  • Rotatable TFT-LCD Display —— Screen supports 4 orientation directions, allowing multiple installation positions
  • Compatible Pipe Materials —— Metal pipe (stainless steel, carbon steel, copper) and plastic pipe (PVDF, PVC, PPR, PPH, PFA, HDPE)
  • Multiple Measurable Media —— Water, chemical liquids, organic liquids, and oils
  • Multiple Output Options —— RS-485 / Modbus RTU, 4–20 mA, and NPN/PNP discrete output

Product Application

Photovoltaic
Semiconductor
Li-ion Battery
Environmental
Agriculture & Animal Husbandry
Pharmaceutical
Liquid Cooling
Food Processing

Technical Data

Measurement
Measurement Principle Ultrasonic transit-time
Pipe Size Range DN8–DN20 (NPS ¼"–¾")
Measurable Media Water / Chemical liquids / Organic liquids / Oils
Flow Units L/min / m³/h / L/h
Displayed Variables Instantaneous flow rate / Accumulated flow total / Flow velocity / Signal quality
Flow Range
DN8 (¼") 1.0–20 L/min
DN10 (⅜") 1.0–30 L/min
DN15 (½") 2.5–60 L/min
DN20 (¾") 2.5–100 L/min
Accuracy & Performance
Accuracy ±1% F.S.
Repeatability 0.15% F.S.
Display Update Rate 0.25 s
Display Resolution 0.01 / 0.1 / 1 (Default: 0.1)
Display
Display Type TFT-LCD, rotatable
Display Orientation 4 directions
Menu Language Chinese / English
Electrical Data
Power Supply 20–30 V DC
Digital Output RS485 Modbus RTU
Analog Output 4–20 mA (0–24 mA / 0–20 mA adjustable)
Discrete Output NPN / PNP
Connector M12 × 1
Cable Length 2,000 mm (78.7 in)
Alarm Output
Instantaneous Flow Mode High-flow / Low-flow threshold alarm
Zone Mode Flow outside a defined range
Totalizer Mode Alarm when accumulated flow reaches a preset value
Environmental Conditions
Liquid Temperature 0°C to +85°C (32°F to +185°F), non-freezing
Ambient Temperature −10°C to +60°C (+14°F to +140°F), non-freezing
Relative Humidity 35–85% RH, non-condensing
Ingress Protection IP54 (IEC 60529)
Mechanical Data & Dimensions
Housing Material Aluminium alloy
Sensor Material PEEK
Sensor Type Integral (one-body)
Installation Method Clamp-on, non-invasive
Installation Tool Single screwdriver
Overall Length 106 mm
Body Width 40 mm
Body Height 50 mm
Metal Pipe Stainless steel / Carbon steel / Copper
Plastic Pipe PVDF / PVC / PPR / PPH / PFA / HDPE
Output Variants
R RS485 Modbus RTU + 4–20 mA
A 4–20 mA + NPN / PNP discrete output
B RS485 Modbus RTU + NPN / PNP discrete output

Certifications & Compliance

Related Products

Ready to upgrade your sensing infrastructure?

You can directly input your requirements and the AI ​​will automatically match the most suitable model.