{"product_id":"sx-psaac-series","title":"SX-PSAAC Series","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cspan\u003eThe SX-PSAAC Series is a digital pressure switch for industrial pressure monitoring and control. It \u003c\/span\u003e\u003cspan\u003ecombines pressure measurement, local display, switching outputs, and 4–20 mA analog output in one \u003c\/span\u003e\u003cspan\u003ecompact device. The switch is available with PNP, NPN, or relay output, and supports multi-unit display, \u003c\/span\u003e\u003cspan\u003eone-touch zero reset, and a 360° rotatable housing for flexible installation\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003eMain Features\u003c\/h2\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0cm;\"\u003e\n\u003cli\u003e\n\u003cdiv\u003e\u003cspan\u003e4-Digit Display\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\u003cspan\u003e 360° rotatable housing\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cspan\u003eMulti-Unit Switching Supports switching between engineering \u003c\/span\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eunits\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\u003cspan\u003eOne-Touch Zero Reset \u003c\/span\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct Application\u003c\/h2\u003e\n\u003ch3\u003eIndustries Served\u003cspan\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003ctable style=\"width: 98.887%; height: 99.1818px;\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 24.8864px;\"\u003e\n\u003ctd style=\"width: 27.7494%; height: 24.8864px;\"\u003e\n\u003cdiv\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eHydraulic \u0026amp; Pneumatic Systems\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 35.5776%; height: 24.8864px;\"\u003e\n\u003cdiv\u003e\u003cspan\u003ePumps \u0026amp; Compressors\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 36.5233%; height: 24.8864px;\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003e Machinery Manufacturing\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.7494%;\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cspan\u003e Water Treatment\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 35.5776%;\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cspan\u003eProcess Technology\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 36.5233%;\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cspan\u003e HVAC\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eTechnical Data\u003c\/h2\u003e\n\u003ctable style=\"width: 99.953%; height: 1248.49px;\" cellpadding=\"0\" cellspacing=\"4\" border=\"0\" class=\"MsoNormalTable\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"break-inside: avoid; height: 35.6px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 98.9408%; height: 35.6px;\"\u003e\u003cstrong\u003eMeasurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"break-inside: avoid; height: 35.6px;\"\u003e\n\u003ctd style=\"width: 35.1468%; height: 35.6px;\"\u003eMeasurement Type\u003c\/td\u003e\n\u003ctd style=\"width: 63.7939%; height: 35.6px;\"\u003eGauge pressure measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"break-inside: avoid; height: 35.6px;\"\u003e\n\u003ctd style=\"width: 35.1468%; height: 35.6px;\"\u003eMeasurement Principle\u003c\/td\u003e\n\u003ctd style=\"width: 63.7939%; height: 35.6px;\"\u003eSputtered thin-film or diffused silicon pressure sensing technology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"break-inside: avoid; height: 35.6px;\"\u003e\n\u003ctd style=\"width: 35.1468%; height: 35.6px;\"\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd style=\"width: 63.7939%; height: 35.6px;\"\u003e−100 kPa to 250 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"break-inside: avoid; height: 35.6px;\"\u003e\n\u003ctd style=\"width: 35.1468%; height: 35.6px;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"width: 63.7939%; height: 35.6px;\"\u003e0.5% FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.1468%;\"\u003eService Life\u003c\/td\u003e\n\u003ctd style=\"width: 63.7939%;\"\u003e100,000,000 load cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"break-inside: avoid; height: 35.6px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 98.9408%; height: 35.6px;\"\u003e\u003cstrong\u003eDisplay \u0026amp; Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 73.3295px;\"\u003e\n\u003ctd style=\"width: 35.1468%; height: 35.6px;\"\u003eDisplay Type\u003c\/td\u003e\n\u003ctd style=\"width: 63.7939%; height: 35.6px;\"\u003e4-digit LCD with pressure display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.1468%;\"\u003eDisplay Functions\u003c\/td\u003e\n\u003ctd style=\"width: 63.7939%;\"\u003eMulti-unit switching \/ One-touch zero reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.1468%;\"\u003eSwitch Output\u003c\/td\u003e\n\u003ctd style=\"width: 63.7939%;\"\u003e2× switch outputs (PNP \/ NPN \/ Relay selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5966px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 98.9408%; height: 35.6px;\"\u003e\u003cstrong\u003ePower \u0026amp; Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.6px;\"\u003e\n\u003ctd style=\"width: 35.1468%; height: 35.6px;\"\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd style=\"width: 63.7939%; height: 35.6px;\"\u003e24 V DC ±20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.6px;\"\u003e\n\u003ctd style=\"width: 35.1468%; height: 35.6px;\"\u003eAnalog Output\u003c\/td\u003e\n\u003ctd style=\"width: 63.7939%; height: 35.6px;\"\u003e4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.1468%;\"\u003eSwitch Output Load Capacity\u003c\/td\u003e\n\u003ctd style=\"width: 63.7939%;\"\u003e≤1.5 A @ 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.6px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 98.9408%; height: 35.6px;\"\u003e\u003cstrong\u003eEnvironmental Conditions\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.1468%;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"width: 63.7939%;\"\u003e−20 to +80°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.1468%;\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd style=\"width: 63.7939%;\"\u003e−40 to +80°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.6px;\"\u003e\n\u003ctd style=\"width: 35.1468%; height: 35.6px;\"\u003eIngress Protection\u003c\/td\u003e\n\u003ctd style=\"width: 63.7939%; height: 35.6px;\"\u003eIP67 (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.1468%;\"\u003eVibration Resistance\u003c\/td\u003e\n\u003ctd style=\"width: 63.7939%;\"\u003e20 g, 10–2,000 Hz (IEC 60068-2-6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.1468%;\"\u003eShock Resistance\u003c\/td\u003e\n\u003ctd style=\"width: 63.7939%;\"\u003e50 g, 6 ms (IEC 60068-2-27)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.6px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 98.9408%; height: 35.6px;\"\u003e\u003cstrong\u003eProcess Connection \u0026amp; Materials\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.6px;\"\u003e\n\u003ctd style=\"width: 35.1468%; height: 35.6px;\"\u003eProcess Connection\u003c\/td\u003e\n\u003ctd style=\"width: 63.7939%; height: 35.6px;\"\u003eM20×1.5 Male \/ G1\/2 Male \/ G1\/4 Male \/ 1\/4\"-18 NPT Male\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.6px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 98.9408%; height: 35.6px;\"\u003e\u003cstrong\u003eTypical Applications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.6px;\"\u003e\n\u003ctd style=\"width: 35.1468%; height: 35.6px;\"\u003eApplications\u003c\/td\u003e\n\u003ctd style=\"width: 63.7939%; height: 35.6px;\"\u003eHydraulic and pneumatic systems, pumps and compressors, machinery manufacturing, water treatment, process technology, and HVAC systems.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eCertifications \u0026amp; Compliance\u003c\/h2\u003e\n\u003cp\u003e\u003cimg alt=\"Certifications \u0026amp; Compliance\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0966\/2362\/4490\/files\/Certifications_Compliance.png?v=1776070827\"\u003e\u003c\/p\u003e","brand":"SensorsX","offers":[{"title":"SX-PSAAC-ENC40C（Pressure Range 0-25MPa）","offer_id":52144346693930,"sku":null,"price":118.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0966\/2362\/4490\/files\/1to1_image_1.png?v=1785311979","url":"https:\/\/sensorsx.com\/products\/sx-psaac-series","provider":"SensorsX","version":"1.0","type":"link"}