{"product_id":"sx-gnh3tsa-series","title":"SX-GNH3TSA Series","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cspan\u003eThe SX-GNH3TSA Series is a potentiostatic electrochemical ammonia \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan\u003esensor. Ammonia and oxygen undergo oxidation–reduction reactions at the \u003c\/span\u003e\u003cspan\u003eworking electrode and counter electrode , respectively, generating an electrical current. The output current is proportional to the ammonia concentration, allowing NH₃ concentration to be determined from the measured current.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003eMain Features\u003c\/h2\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0cm;\"\u003e\n\u003cli\u003e\n\u003cdiv\u003e\u003cspan\u003e High Accuracy, Long Life\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\u003cspan\u003eFast Response, fast return to zero\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eLow Power Consumption, High Sensitivity\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\u003cspan\u003eWide Linear Range, Strong Interference Resistance\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003eHigh Repeatability and Stability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct Application\u003c\/h2\u003e\n\u003ctable style=\"width: 98.777%; height: 98.6px;\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 24.7437px;\"\u003e\n\u003ctd style=\"width: 45.1222%; height: 24.7437px;\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cspan\u003eAmmonia gas alarm instruments\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 54.6719%; height: 24.7437px;\"\u003e\n\u003cdiv\u003e\n\u003cspan\u003e\u003c\/span\u003e\n\u003cdiv\u003e\u003cspan\u003eIndustrial on-site ammonia gas \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003edetection\u003c\/span\u003e\u003c\/div\u003e\n\u003cspan\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24.7563px;\"\u003e\n\u003ctd style=\"width: 45.1222%; height: 24.7563px;\"\u003e\n\u003cdiv\u003e\n\u003cspan\u003e\u003c\/span\u003e\n\u003cdiv\u003e\n\u003cspan\u003eAgriculture and livestock-farming \u003c\/span\u003e\u003cspan\u003eammonia detection\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cspan\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 54.6719%; height: 24.7563px;\"\u003e\n\u003cdiv\u003e\n\u003cspan\u003e\u003c\/span\u003e\n\u003cdiv\u003e\u003cspan\u003eSmart municipal ammonia detection\u003c\/span\u003e\u003c\/div\u003e\n\u003cspan\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45.1222%;\"\u003e\n\u003cdiv\u003e\n\u003cspan\u003eAtmospheric \/ ambient ammonia \u003c\/span\u003e\u003cspan\u003edetection\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 54.6719%;\"\u003e\n\u003cdiv\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eTechnical Data\u003c\/h2\u003e\n\u003ctable style=\"width: 99.953%; height: 1351.2px;\" cellpadding=\"0\" cellspacing=\"4\" border=\"0\" class=\"MsoNormalTable\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"break-inside: avoid; height: 34px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 99.1815%; height: 34px;\"\u003e\u003cstrong\u003eMeasurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"break-inside: avoid; height: 39.2px;\"\u003e\n\u003ctd style=\"width: 24.0732%; height: 39.2px;\"\u003eExample Model\u003c\/td\u003e\n\u003ctd style=\"width: 75.1083%; height: 39.2px;\"\u003eSX-GNH3TSA-340\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"break-inside: avoid; height: 39.2px;\"\u003e\n\u003ctd style=\"width: 24.0732%; height: 39.2px;\"\u003eDetection Principle\u003c\/td\u003e\n\u003ctd style=\"width: 75.1083%; height: 39.2px;\"\u003eThree-electrode electrochemical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"break-inside: avoid; height: 73.2px;\"\u003e\n\u003ctd style=\"width: 24.0732%; height: 73.2px;\"\u003eDetection Gas\u003c\/td\u003e\n\u003ctd style=\"width: 75.1083%; height: 73.2px;\"\u003eAmmonia (NH₃)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 24.0732%; height: 39.2px;\"\u003eDetection Range\u003c\/td\u003e\n\u003ctd style=\"width: 75.1083%; height: 39.2px;\"\u003e0–100 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 24.0732%; height: 39.2px;\"\u003eMaximum Overload Concentration\u003c\/td\u003e\n\u003ctd style=\"width: 75.1083%; height: 39.2px;\"\u003e200 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"break-inside: avoid; height: 53.6px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 99.1815%; height: 53.6px;\"\u003e\u003cstrong\u003eSensitivity \u0026amp; Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 73.2px;\"\u003e\n\u003ctd style=\"width: 24.0732%; height: 73.2px;\"\u003eSensitivity\u003c\/td\u003e\n\u003ctd style=\"width: 75.1083%; height: 73.2px;\"\u003e160 ± 40 nA\/ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"break-inside: avoid; height: 39.2px;\"\u003e\n\u003ctd style=\"width: 24.0732%; height: 39.2px;\"\u003eZero Drift\u003c\/td\u003e\n\u003ctd style=\"width: 75.1083%; height: 39.2px;\"\u003e0–1 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.0732%; height: 19.6px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 75.1083%; height: 19.6px;\"\u003e1 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.0732%; height: 19.6px;\"\u003eRepeatability\u003c\/td\u003e\n\u003ctd style=\"width: 75.1083%; height: 19.6px;\"\u003e2% of output signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.0732%; height: 19.6px;\"\u003eLinearity\u003c\/td\u003e\n\u003ctd style=\"width: 75.1083%; height: 19.6px;\"\u003eLinear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.0732%; height: 19.6px;\"\u003eOutput\u003c\/td\u003e\n\u003ctd style=\"width: 75.1083%; height: 19.6px;\"\u003eCurrent proportional to NH₃ concentration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 99.1815%; height: 19.6px;\"\u003e\u003cstrong\u003eResponse\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 24.0732%; height: 39.2px;\"\u003eResponse Time\u003c\/td\u003e\n\u003ctd style=\"width: 75.1083%; height: 39.2px;\"\u003e\u0026lt; 90 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 99.1815%; height: 19.6px;\"\u003e\u003cstrong\u003eStability \u0026amp; Service Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 24.0732%; height: 39.2px;\"\u003eLong-Term Stability\u003c\/td\u003e\n\u003ctd style=\"width: 75.1083%; height: 39.2px;\"\u003e\u0026lt; 2% signal\/month\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 24.0732%; height: 39.2px;\"\u003eShelf Life\u003c\/td\u003e\n\u003ctd style=\"width: 75.1083%; height: 39.2px;\"\u003e12 months after delivery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 24.0732%; height: 39.2px;\"\u003eOperating Life\u003c\/td\u003e\n\u003ctd style=\"width: 75.1083%; height: 39.2px;\"\u003e2 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 99.1815%; height: 19.6px;\"\u003e\u003cstrong\u003eElectrical Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.0732%; height: 19.6px;\"\u003eBias Voltage\u003c\/td\u003e\n\u003ctd style=\"width: 75.1083%; height: 19.6px;\"\u003e0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.0732%; height: 19.6px;\"\u003eLoad Resistance\u003c\/td\u003e\n\u003ctd style=\"width: 75.1083%; height: 19.6px;\"\u003e5–30 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 99.1815%; height: 19.6px;\"\u003e\u003cstrong\u003eEnvironmental Conditions\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 24.0732%; height: 39.2px;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"width: 75.1083%; height: 39.2px;\"\u003e−30°C to +50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 24.0732%; height: 39.2px;\"\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd style=\"width: 75.1083%; height: 39.2px;\"\u003e15–90% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 24.0732%; height: 39.2px;\"\u003eOperating Pressure\u003c\/td\u003e\n\u003ctd style=\"width: 75.1083%; height: 39.2px;\"\u003e90–110 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 99.1815%; height: 19.6px;\"\u003e\u003cstrong\u003eMechanical Data\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 24.0732%; height: 39.2px;\"\u003eOverall Dimensions\u003c\/td\u003e\n\u003ctd style=\"width: 75.1083%; height: 39.2px;\"\u003eApprox. Ø20 × 16.95 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 24.0732%; height: 39.2px;\"\u003ePin Length\u003c\/td\u003e\n\u003ctd style=\"width: 75.1083%; height: 39.2px;\"\u003e4.40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.0732%; height: 19.6px;\"\u003ePin Diameter\u003c\/td\u003e\n\u003ctd style=\"width: 75.1083%; height: 19.6px;\"\u003eØ1.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 24.0732%; height: 39.2px;\"\u003eDimensional Tolerance\u003c\/td\u003e\n\u003ctd style=\"width: 75.1083%; height: 39.2px;\"\u003e±0.2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 99.1815%; height: 19.6px;\"\u003e\u003cstrong\u003eCross Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 24.0732%; height: 39.2px;\"\u003eCarbon Monoxide CO\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 75.1083%; height: 39.2px;\"\u003e0 ppm NH₃ reading at 75 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.0732%; height: 19.6px;\"\u003eCarbon Dioxide CO₂\u003c\/td\u003e\n\u003ctd style=\"width: 75.1083%; height: 19.6px;\"\u003e0 ppm NH₃ reading at 100 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 24.0732%; height: 39.2px;\"\u003eHydrogen Sulfide H₂S\u003c\/td\u003e\n\u003ctd style=\"width: 75.1083%; height: 39.2px;\"\u003e35 ppm NH₃ reading at 50 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.0732%; height: 19.6px;\"\u003eHydrogen H₂\u003c\/td\u003e\n\u003ctd style=\"width: 75.1083%; height: 19.6px;\"\u003e0 ppm NH₃ reading at 1000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 24.0732%; height: 39.2px;\"\u003eButene C₄H₈\u003c\/td\u003e\n\u003ctd style=\"width: 75.1083%; height: 39.2px;\"\u003e0 ppm NH₃ reading at 100 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eCertifications \u0026amp; Compliance\u003c\/h2\u003e\n\u003cp style=\"white-space: nowrap;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0966\/2362\/4490\/files\/b1.3.png?v=1785304108\" alt=\"\" style=\"display: inline-block; vertical-align: middle;\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0966\/2362\/4490\/files\/b1.2.png?v=1785304108\" alt=\"\" style=\"display: inline-block; vertical-align: middle;\"\u003e \u003c\/p\u003e","brand":"SensorsX","offers":[{"title":"SX-GNH3TSA-340（Gas range 0-100PPM）","offer_id":52164397596970,"sku":null,"price":104.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0966\/2362\/4490\/files\/p.5-1_0ff0fae2-5462-48da-8608-b6be62b569df.png?v=1785825452","url":"https:\/\/sensorsx.com\/es\/products\/sx-gnh3tsa-series","provider":"SensorsX","version":"1.0","type":"link"}