{"product_id":"sx-ctnma-series","title":"SX-CTNMA Series","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cspan\u003eThe SX-CTNMA Series online turbidity analyzer is designed for low-turbidity water quality monitoring. It \u003c\/span\u003e\u003cspan\u003efeatures ultra-low turbidity measurement capability, high-precision detection, extended maintenance \u003c\/span\u003e\u003cspan\u003eintervals, water-saving operation, and digital communication. Remote monitoring is supported through \u003c\/span\u003e\u003cspan\u003ecloud platforms and mobile devices. The analyzer is widely used for waterworks inlet\/outlet monitoring, \u003c\/span\u003e\u003cspan\u003esecondary water supply, pipe-network terminal water, direct drinking water, membrane-filtered water, \u003c\/span\u003e\u003cspan\u003eswimming pools, and surface water monitoring.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003ch2\u003eMain Features\u003c\/h2\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cdiv\u003e\n\u003cspan\u003eUses the ISO 7027-compliant 90° scattering measurement \u003c\/span\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003emethod\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cdiv\u003e\n\u003cspan\u003eOptimized optical path and detection structure combined with a \u003c\/span\u003e\u003cspan\u003ereal-time compensation algorithm for high-precision turbidity measurement\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cdiv\u003e\n\u003cspan\u003e Built-in cleaning wiper\/brush to meet long-term stable online \u003c\/span\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003emonitoring needs\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\u003cspan\u003eIntegrated defoaming and measurement unit that reduces inletwater bubble interference, improving measurement stability and accuracy\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cdiv\u003e\n\u003cspan\u003eBuilt-in calibration parameters, factory-calibrated for immediate installation and use \u003c\/span\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003e \u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct Application\u003c\/h2\u003e\n\u003ch3\u003eIndustries Served\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; height: 133.188px;\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 74.3875px;\"\u003e\n\u003ctd style=\"width: 29.0368%; height: 74.3875px;\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cspan\u003eWaterworks Inlet \/ Outlet Monitoring\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 37.7715%; height: 74.3875px;\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eSecondary Water Supply\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 33.2861%; height: 74.3875px;\"\u003e\n\u003cdiv\u003e\u003cspan\u003ePipe-Network Terminal Water\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 29.0368%; height: 39.2px;\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cspan\u003eDirect Drinking Water\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 37.7715%; height: 39.2px;\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cspan\u003eMembrane-Filtered Water\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 33.2861%; height: 39.2px;\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cspan\u003eSwimming Pools\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 29.0368%; height: 19.6px;\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cspan\u003eSurface Water\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 37.7715%; height: 19.6px;\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 33.2861%; height: 19.6px;\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eTechnical Data\u003c\/h2\u003e\n\u003ctable style=\"width: 99.953%; height: 1145.36px;\" cellpadding=\"0\" cellspacing=\"4\" border=\"0\" class=\"MsoNormalTable\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"break-inside: avoid; height: 63.8125px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 98.9408%; height: 63.8125px;\"\u003e\u003cstrong\u003eMeasurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"break-inside: avoid; height: 70.1438px;\"\u003e\n\u003ctd style=\"width: 49.8315%; height: 70.1438px;\"\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.1093%; height: 70.1438px;\"\u003e\u003cspan\u003eLow-Range Turbidity Analyzer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"break-inside: avoid; height: 70.1438px;\"\u003e\n\u003ctd style=\"width: 49.8315%; height: 70.1438px;\"\u003e\u003cspan\u003eMeasurement Principle\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.1093%; height: 70.1438px;\"\u003e\u003cspan\u003e90° light scattering method\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"break-inside: avoid; height: 70.1438px;\"\u003e\n\u003ctd style=\"width: 49.8315%; height: 70.1438px;\"\u003e\u003cspan\u003eMeasurement Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.1093%; height: 70.1438px;\"\u003e\u003cspan\u003e0–10 NTU, other ranges customizable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 49.8315%; height: 19.6px;\"\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.1093%; height: 19.6px;\"\u003e\u003cspan\u003e0.001 NTU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"break-inside: avoid; height: 63.8125px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 98.9408%; height: 63.8125px;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"break-inside: avoid; height: 63.8125px;\"\u003e\n\u003ctd style=\"width: 49.8315%; height: 63.8125px;\"\u003e\u003cspan\u003eTurbidity Accuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.1093%; height: 63.8125px;\"\u003e\u003cspan\u003e±0.01 NTU or ±2% (whichever is greater)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 63.8125px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 98.9408%; height: 63.8125px;\"\u003e\u003cstrong\u003e\u003cspan lang=\"EN-US\"\u003ePower \u0026amp; Communication\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 70.1438px;\"\u003e\n\u003ctd style=\"width: 49.8315%; height: 70.1438px;\"\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd style=\"width: 49.1093%; height: 70.1438px;\"\u003e\u003cspan\u003eDC 12–24 V, \u0026gt;1 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 104.619px;\"\u003e\n\u003ctd style=\"width: 49.8315%; height: 104.619px;\"\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.1093%; height: 104.619px;\"\u003e0.4 W idle \/ 1 W while brushing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 70.1438px;\"\u003e\n\u003ctd style=\"width: 49.8315%; height: 70.1438px;\"\u003eDigital Communication\u003c\/td\u003e\n\u003ctd style=\"width: 49.1093%; height: 70.1438px;\"\u003e\u003cspan\u003eRS-485 \/ Modbus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 63.8125px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 98.9408%; height: 63.8125px;\"\u003e\u003cstrong\u003eEnvironmental Conditions\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 63.8125px;\"\u003e\n\u003ctd style=\"width: 49.8315%; height: 63.8125px;\"\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.1093%; height: 63.8125px;\"\u003e\u003cspan\u003e0–50 °C (32–122 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.6688px;\"\u003e\n\u003ctd style=\"width: 49.8315%; height: 35.6688px;\"\u003e\u003cspan\u003eRequired Flow Rate\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.1093%; height: 35.6688px;\"\u003e\u003cspan\u003e180–500 mL\/min\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 63.8125px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 98.9408%; height: 63.8125px;\"\u003e\u003cstrong\u003e\u003cspan lang=\"EN-US\"\u003eMechanical \u0026amp; Materials\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 49.8315%; height: 39.2px;\"\u003e\u003cspan\u003ePiping Connections\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.1093%; height: 39.2px;\"\u003e\u003cspan\u003eInlet: 1\/4 in (DN6) PE tubing; Overflow: 3\/8 in (DN8) PE tubing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.525px;\"\u003e\n\u003ctd style=\"width: 49.8315%; height: 39.525px;\"\u003e\u003cspan\u003eHousing Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.1093%; height: 39.525px;\"\u003e\u003cspan\u003eSample Chamber: PC + ABS; Sensor: 316L + POM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 70.1438px;\"\u003e\n\u003ctd style=\"width: 49.8315%; height: 70.1438px;\"\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.1093%; height: 70.1438px;\"\u003e\u003cspan\u003eΦ54.6 mm × 193.5 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 49.8315%; height: 39.2px;\"\u003e\u003cspan\u003eMaintenance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.1093%; height: 39.2px;\"\u003eSelf-cleaning optical-window wiper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eCertifications \u0026amp; Compliance\u003c\/h2\u003e\n\u003cp style=\"white-space: nowrap;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0966\/2362\/4490\/files\/b1.3.png?v=1785304108\" alt=\"\" style=\"display: inline-block; vertical-align: middle;\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0966\/2362\/4490\/files\/b1.2.png?v=1785304108\" alt=\"\" style=\"display: inline-block; vertical-align: middle;\"\u003e\u003c\/p\u003e","brand":"SensorsX","offers":[{"title":"SX-CTNMA-11（Turbidity range 0-10NTU ）","offer_id":52372583055658,"sku":null,"price":1265.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0966\/2362\/4490\/files\/p.6-1_1c28232c-68b6-458a-aeca-b8f21f4379a1.png?v=1787720239","url":"https:\/\/sensorsx.com\/es\/products\/sx-ctnma-series","provider":"SensorsX","version":"1.0","type":"link"}