{"title":"Conductivity Sensors","description":"\u003cp\u003eAs core tools for evaluating water purity and salinity, these sensors infer total dissolved solids by measuring the ability of a solution to conduct current. With precise temperature compensation, they withstand high pressure and corrosion in industrial fluids. They are widely used in power boiler water quality monitoring, seawater desalination, and reverse-osmosis pure water preparation systems, serving as key sensing elements for stable operation of industrial circulating water systems and process fluid quality.\u003c\/p\u003e","products":[{"product_id":"sx-ccfma-series","title":"SX-CCFMA Series","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"EN-US\"\u003eThe SX-CCFMA Series online conductivity\/salinity sensor uses advanced four-electrode measurement technology with an RS-485 digital interface and Modbus protocol support. Compared with traditional twoelectrode sensors, it provides higher accuracy, a wider measurement range, and improved stability. The probe includes a built-in temperature sensor, and automatic temperature compensation helps maintain measurement accuracy across varying temperatures.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eMain Features\u003c\/h2\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cspan lang=\"EN-US\"\u003eFour-Electrode Measurement Technology\u003c\/span\u003e\u003cspan lang=\"EN-US\"\u003e Advanced four-electrode technology provides higher accuracy, wider measurement range, and improved stability compared with traditional two-electrode sensors\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cspan lang=\"EN-US\"\u003eWide Measurement Range\u003c\/span\u003e\u003cspan lang=\"EN-US\"\u003e Conductivity range up to 0–200 mS\/cm, with salinity measurement up to 0–175 ppt and TDS up to 128,000 mg\/L\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cspan lang=\"EN-US\"\u003eMulti-Parameter Measurement\u003c\/span\u003e\u003cspan lang=\"EN-US\"\u003e Simultaneous measurement of conductivity, salinity, TDS, and temperature\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cspan lang=\"EN-US\"\u003eRS-485 Modbus Communication\u003c\/span\u003e\u003cspan lang=\"EN-US\"\u003e Supports standard Modbus protocol for easy integration with industrial control systems\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cspan lang=\"EN-US\"\u003eAutomatic Temperature Compensation\u003c\/span\u003e\u003cspan lang=\"EN-US\"\u003e Built-in temperature sensor with automatic compensation to maintain measurement accuracy under varying temperatures\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cspan lang=\"EN-US\"\u003eCorrosion-Resistant Design\u003c\/span\u003e\u003cspan lang=\"EN-US\"\u003e PEEK and titanium alloy housing with IP68 protection, suitable for long-term submersible operation\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cspan lang=\"EN-US\"\u003eFactory Calibration\u003c\/span\u003e\u003cspan lang=\"EN-US\"\u003e Built-in calibration parameters for quick installation and commissioning\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e\n\u003cspan lang=\"EN-US\"\u003eFlexible Applications\u003c\/span\u003e\u003cspan lang=\"EN-US\"\u003e Suitable for water quality monitoring, industrial process water, wastewater treatment, and environmental monitoring\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct Application\u003c\/h2\u003e\n\u003ch3\u003eIndustries Served\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; height: 58.7813px;\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 29.0323%; height: 39.1875px;\"\u003e\u003cspan lang=\"EN-US\"\u003eWater quality monitoring\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 37.8303%; height: 39.1875px;\"\u003e\u003cspan lang=\"EN-US\"\u003eConductivity \/ salinity \/ TDS measurement\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 33.1375%; height: 39.1875px;\"\u003e\u003cspan lang=\"EN-US\"\u003eIndustrial and environmental water monitoring\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eTechnical Data\u003c\/h2\u003e\n\u003ctable style=\"width: 99.953%; height: 1349.91px;\" cellpadding=\"0\" cellspacing=\"4\" border=\"0\" class=\"MsoNormalTable\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"break-inside: avoid; height: 40.7375px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 99.1908%; height: 40.7375px;\"\u003e\u003cstrong\u003eMeasurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"break-inside: avoid; height: 44.8375px;\"\u003e\n\u003ctd style=\"width: 51.7414%; height: 44.8375px;\"\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 47.4494%; height: 44.8375px;\"\u003e\u003cspan\u003eConductivity \/ Salinity Sensor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"break-inside: avoid; height: 40.7375px;\"\u003e\n\u003ctd style=\"width: 51.7414%; height: 40.7375px;\"\u003e\u003cspan\u003eMeasurement\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 47.4494%; height: 40.7375px;\"\u003e\u003cspan\u003eFour-electrode conductivity\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"break-inside: avoid; height: 44.8375px;\"\u003e\n\u003ctd style=\"width: 51.7414%; height: 44.8375px;\"\u003e\u003cspan\u003ePrinciple\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 47.4494%; height: 44.8375px;\"\u003e\u003cspan\u003emeasurement technology\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"break-inside: avoid; height: 67.15px;\"\u003e\n\u003ctd style=\"width: 51.7414%; height: 67.15px;\"\u003e\u003cspan\u003eConductivity Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 47.4494%; height: 67.15px;\"\u003e\u003cspan\u003e0–200 mS\/cm (0–2 mS\/cm, 2–20 mS\/cm, 20–200 mS\/cm sub-ranges)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 44.8375px;\"\u003e\n\u003ctd style=\"width: 51.7414%; height: 44.8375px;\"\u003e\u003cspan\u003eSalinity Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 47.4494%; height: 44.8375px;\"\u003e\u003cspan\u003e0–175 ppt\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 44.8375px;\"\u003e\n\u003ctd style=\"width: 51.7414%; height: 44.8375px;\"\u003e\u003cspan\u003eTDS Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 47.4494%; height: 44.8375px;\"\u003e\u003cspan\u003e0–128,000 mg\/L\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"break-inside: avoid; height: 40.7375px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 99.1908%; height: 40.7375px;\"\u003e\u003cstrong\u003eAccuracy \u0026amp; \u003cspan lang=\"EN-US\"\u003eCalibration\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 81.8562px;\"\u003e\n\u003ctd style=\"width: 51.7414%; height: 81.8562px;\"\u003e\u003cspan\u003eConductivity Accuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 47.4494%; height: 81.8562px;\"\u003e\u003cspan\u003e±1% or ±0.01 mS\/cm (whichever is greater)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"break-inside: avoid; height: 40.7375px;\"\u003e\n\u003ctd style=\"width: 51.7414%; height: 40.7375px;\"\u003e\u003cspan\u003eSalinity Accuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 47.4494%; height: 40.7375px;\"\u003e\u003cspan\u003e±1 ppt\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 25.025px;\"\u003e\n\u003ctd style=\"width: 51.7414%; height: 25.025px;\"\u003eCalibration\u003c\/td\u003e\n\u003ctd style=\"width: 47.4494%; height: 25.025px;\"\u003e1–point or 2–point calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 40.7375px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 99.1908%; height: 40.7375px;\"\u003e\u003cstrong\u003e\u003cspan lang=\"EN-US\"\u003ePower \u0026amp; Communication\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 44.8375px;\"\u003e\n\u003ctd style=\"width: 51.7414%; height: 44.8375px;\"\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd style=\"width: 47.4494%; height: 44.8375px;\"\u003e\u003cspan\u003eDC 9–24 V, \u0026gt;500 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 67.15px;\"\u003e\n\u003ctd style=\"width: 51.7414%; height: 67.15px;\"\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 47.4494%; height: 67.15px;\"\u003e\u003cspan\u003e0.2 W typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 44.8375px;\"\u003e\n\u003ctd style=\"width: 51.7414%; height: 44.8375px;\"\u003eDigital Communication\u003c\/td\u003e\n\u003ctd style=\"width: 47.4494%; height: 44.8375px;\"\u003e\u003cspan\u003eRS-485 \/ Modbus RTU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 40.7375px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 99.1908%; height: 40.7375px;\"\u003e\u003cstrong\u003eEnvironmental Conditions\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 40.7375px;\"\u003e\n\u003ctd style=\"width: 51.7414%; height: 40.7375px;\"\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 47.4494%; height: 40.7375px;\"\u003e\u003cspan\u003e0–50 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.525px;\"\u003e\n\u003ctd style=\"width: 51.7414%; height: 22.525px;\"\u003e\u003cspan\u003eIngress Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 47.4494%; height: 22.525px;\"\u003e\u003cspan\u003eIP68\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 40.7375px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 99.1908%; height: 40.7375px;\"\u003e\u003cstrong\u003e\u003cspan lang=\"EN-US\"\u003eMechanical \u0026amp; Materials\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 89.4563px;\"\u003e\n\u003ctd style=\"width: 51.7414%; height: 89.4563px;\"\u003e\u003cspan\u003eHousing Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 47.4494%; height: 89.4563px;\"\u003e\u003cspan\u003ePEEK + Titanium Alloy\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 25.025px;\"\u003e\n\u003ctd style=\"width: 51.7414%; height: 25.025px;\"\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 47.4494%; height: 25.025px;\"\u003e\u003cspan\u003eΦ22 mm × 175.5 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 44.8375px;\"\u003e\n\u003ctd style=\"width: 51.7414%; height: 44.8375px;\"\u003e\u003cspan\u003eCable Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 47.4494%; height: 44.8375px;\"\u003e\u003cspan\u003e10 m standard, customizable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eCertifications \u0026amp; Compliance\u003c\/h2\u003e\n\u003cp style=\"white-space: nowrap;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0966\/2362\/4490\/files\/b1.3.png?v=1785304108\" alt=\"\" style=\"display: inline-block; vertical-align: middle;\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0966\/2362\/4490\/files\/b1.2.png?v=1785304108\" alt=\"\" style=\"display: inline-block; vertical-align: middle;\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0966\/2362\/4490\/files\/b1.4_0f9dfc9d-95cf-476d-974a-96e0bade96ab.png?v=1785389486\" alt=\"\" style=\"display: inline-block; vertical-align: middle;\"\u003e\n  \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0966\/2362\/4490\/files\/b1.12.png?v=1785404365\" alt=\"\" style=\"display:inline-block;vertical-align:middle;\"\u003e\n\u003c\/p\u003e","brand":"SensorsX","offers":[{"title":"SX-CCFMA-11121（Measurement Range 0-200 mS\/cm）","offer_id":52119821254954,"sku":null,"price":500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0966\/2362\/4490\/files\/SX-CCFMASeries.jpg?v=1784770425"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0966\/2362\/4490\/collections\/Conductivity_Salinity_Sensor.jpg?v=1785737679","url":"https:\/\/sensorsx.com\/collections\/conductivity-sensors.oembed","provider":"SensorsX","version":"1.0","type":"link"}